[arve url=”https://vimeo.com/410170923″ thumbnail=”7500″ /]
Use and Care of the Hall Lithium Battery line. Now available for veterinary use.
[arve url=”https://vimeo.com/410170923″ thumbnail=”7500″ /]
Use and Care of the Hall Lithium Battery line. Now available for veterinary use.
[arve url=”https://vimeo.com/370509022″ title=”Voyant Vessel Sealing Technology by Applied Medical” description=”Voyant Vessel Sealing Technology by Applied Medical” /]
Voyant is an easy to use, cost-effective vessel sealer that provides secure hemostasis for laparoscopic and open veterinary surgical procedures.
Continue reading Voyant Vessel Sealing Technology by Applied Medical
If you need to print this PDF or save for later
click below to download your copy.
[button size=”medium” style=”secondary” text=”Download PDF” link=”https://vetovationnew.instawp.xyz/wp-content/uploads/2020/09/Plasma-In-Service-Preparation_1-.pdf” target=”none”]
Thank you for purchasing the Sterlink System
If you need to print this PDF or save for later
click below to download your copy.
[button size=”medium” style=”secondary” text=”Download PDF” link=”https://vetovationnew.instawp.xyz/wp-content/uploads/2020/09/Sterlink-FPS-EN-User-Manual-Rev03-January-2019-NEW-Copy.pdf” target=”none”]
by Plasmapp Co., Ltd.
Distributed by Vetovation Inc.
Revised in Jan. 2019
1.1 Personal safety and first aid
1.2 Personal protective equipment
1.3 Warning, cautions, and note
1.4 Symbols
Ā 2.1 Intended use
2.2 Sterilization procedure
2.3 Sterilization cycle
2.4 Sterilizer system and accessories
2.5 Sterilant cassettes
3.1 Indications for use
3.2 What can be sterilized
3.3 Items not to be processed
3.4 Guidelines for preparing items to be sterilized
3.5 Cleaning, rinsing, and drying
3.6 Packaging and loading
3.6.1.Instrument tray
3.6.2 Tray mats
3.6.3 Packaging
3.6.4 Loading
4.1 Before you start
4.2 Start and warm-up
4.3 Preparing the load
4.4 Cassette Loading
4.5 Starting sterilization cycle
4.6 Cycle in progress and completed
4.7 Cancelling sterilization cycle
4.8 Processing a sterilized load
4.8.1 Inspecting chemical indicator
4.8.2 Processing self-contained biological indicator
5.1 Overview
5.2 Access levels
5.3 Additional utility menu
6.1 Reports
6.2 Data
7.1 Manual maintenance
7.1.1 Cleaning the sterilizer exterior and interior chamber
7.1.2 Replacing label-printer paper
7.1.3 Routine sterilizer maintenance
7.2 Sterilant cassettes
7.3 Moving, long term stop and disposal of the sterilizer
8.1 System features
8.2 Software update
8.3 User errors
8.4 Sterilant cassette errors
8.5 Other system errors
8.6 Contact information
Your safety is the primary concern of Plasmapp Co., Ltd. and this chapter provides information on safely using the gas plasma sterilizer system. You must read and understand the safety information and instruction given in this chapter before operating the sterilizer. Always pay attention to the warnings, cautions and notes throughout this User manual. This information is for your safety and will make sure that you receive the best result from the safe operation of your sterilizer system.
WARNING! HYDROGEN PEROXIDE IS CORROSIVE.
Concentrated hydrogen peroxide is corrosive to skin, eyes, nose, throat, lungs, and the gastrointestinal tract. Always wear latex, PVC (vinyl), or nitrile gloves while removing items from the sterilizer following any cancelled cycle or error occurrence. Residual hydrogen peroxide may be present. If the contact occurs, immediately flush skin with large amounts of water. If symptoms are severe or persist, consult a doctor immediately.
WARNING! HYDROGEN PEROXIDE IS AN OXIDIZER.
Avoid allowing hydrogen peroxide to contact organic materials, including paper, cotton, wood, or lubricants. Concentrated hydrogen peroxide is a strong oxidizer and may react with organic materials, causing ignition and fire.
WARNING! RISK OF EYE INJURY.
Direct hydrogen peroxide contact with eyes can cause irreversible tissue damage. If there is a contact with eyes, immediately rinse eyes thoroughly with a large amount of water. Consult a physician immediately.
WARNING! RISK OF SKIN INJURY.
Direct contact between the skin and hydrogen peroxide can cause severe irritation. If the contact occurs, immediately flush skin with large amounts of water. If symptoms are severe or persist, consult a physician immediately.
WARNING! RISK OF RESPIRATORY IRRITATION.
Inhalation of hydrogen peroxide mist can cause severe irritation of lungs, throat, and nose. If you inhale it, move to fresh air. Please consult a doctor immediately if the symptoms are severe or persist.
WARNING! CONCENTRATED HYDROGEN PEROXIDE IS TOXIC.
Ingestion of hydrogen peroxide may be life-threatening. If swallowed, drink plenty of water immediately to dilute. Do not try to induce vomiting. Please consult a doctor immediately if the symptoms are severe or persist.
WARNING! STERILIZATION SURFACES.
At the end of a cycle, the interior of the sterilizer may be hot. Do not touch the inside of the chamber or door with your bare or gloved hands. Allow the sterilizer to cool before touching interior surfaces.
CAUTION! HYDROGEN PEROXIDE MAY BE PRESENT.
Wear latex, PVC (vinyl), or nitrile gloves whenever handling a load after a cycle cancellation or error occurrence. Hydrogen peroxide liquid may be present on the load or in the chamber.
Warnings and cautions are accompanied by symbols surrounded by a triangle and are printed in the text in boldface italics. Warnings indicate events or conditions that can result in serious injury or death. Cautions indicate events or conditions that can result in severe damage to the equipment.
Notes are accompanied by a check mark and are printed in italics. Notes highlight specific information about the proper use and maintenance of the STERLINKā FPS- 15s Plus Sterilizer system.
HOT SURFACES PRESENT.
Do not touch without protection.
HAZARDOUS CHEMICAL PRESENT.
Use personal protective equipment.
TOXIC CHEMICAL PRESENT.
Avoid exposure, contact, or ingestion.
HAND CRUSH HAZARD.
Keep hands clear while operating.
The STERLINKĀ® FPS-15s Plus sterilization system is a low temperature gas plasma sterilizer to inactivate microorganisms for a broad range of metal and nonmetal medical devices and surgical instruments at low temperature. This sterilizer offers an effective, safe, fast, economical, easyāto- use, reliable, and flexible sterilization method.
When used as directed by the instruction in this User manual, please review the Chapter 4 “Load preparation” chapter in which recommended materials and lumen sizes are described. When selecting reusable medical devices to be processed in this sterilizer system, reprocessing information should be obtained from the manufacturer of the medical device in accordance with international norms (such as ISO 17664 or AAMI TIR 12).
As a medical professional, you may already be familiar with general sterilization principles. However, the STERLINKĀ® FPS-15s Plus sterilizer utilize its own method, and it requires special attention to the ways in which it differs from other conventional sterilizers.
The STERLINKĀ® FPS-15s Plus sterilizer can sterilize medical devices by diffusing hydrogen peroxide vapor into the chamber or pouch. It rapidly sterilizes medical instruments and materials without leaving toxic residues. All stages of the plasma sterilization cycle are not damaged to compatible instruments which are sensitive to heat and moisture.
The STERLINKĀ® FPS-15s Plus sterilizer can be used for metal and non-metal medical devices and can sterilize instruments that have difficult-to-reach (diffusion-restricted) spaces, such as hinges on forceps. Please refer to “Load preparation” chapter for more information.
The sterilizer consistently provides the Sterility Assurance Level (SAL) of 10-6, as defined by U.S. Food and Drug Administration (FDA) and international standards, for clinical use on all allowed substrates within the limits of the claims for materials and geometries when used in accordance with the directions in this User manual.
The devices have been pre-validated to the SAL of 10-6 based upon worst-case conditions, including lumens within the claim lengths and mated surfaces. If additional technical information concerning validation is needed, please contact Plasmapp or your local Plasmapp customer support representative.
The STERLINKĀ® FPS-15s Plus sterilizer is designed to be operated at two different modes, and each mode is the combined cycle of the Smart Ready (SRTM), Sterilization and Smart Complete (SCTM) process. The plasma sterilizers system is designed to operate only with the sterilant cassettes of STERPACKĀ®, STERPACKĀ® Plus and STERLOADĀ®. Each cassette has individual barcode which is scanned by the sterilizer to start the sterilization cycle automatically according to the barcode identifying the type of the cassettes. This automatic scan step reduces user error and the reliability of sterilization.
The optimized heating and drying process is provided in the SRTM process by measuring volume of the medical devices and residual water left on the devices in which the pressure of the pouch and chamber is independently controlled to obtain the venting and pumping pressure curves.
The sterilization process consists of the two consecutive identical phases, and the critical process parameters are controlled to be identical. The validation of the sterilization process is performed by using the half-cycle overkill method to demonstrate the 10-6 SAL. In the SCTM process the sterilizing agent is removed before using the sterilized medical devices to maintain the asepsis. To ensure user safety we use an independent pressure sensor of the sterilizer to measure the residual sterilant and perform an optimized completion process. The following table provides a brief description for each cycle mode.
Sterilization cycle and minimum time by mode
Mode |
Sterilant cassette |
Cycle and minimum cycle time (unit: min) |
||
SRTM / SCTM |
Sterilization |
Total |
||
POUCH |
STERPACKā |
3 |
4 |
7 |
POUCH Plus |
STERPACKāPlus |
6 |
8 |
14 |
CHAMBER |
STERLOADā |
21 |
15 |
36 |
Sterilization process – Phase 1
Sterilization process – Phase 2
The steps in the Phase 1 are repeated.
The STERLINKĀ® FPS-15s Plus sterilization system has accessories of the sterilizer cart and label-printer. The following figure shows the complete sterilizer system including the accessories.
Ā
Figure 3.1 STERLINKĀ® FPS-15s Plus sterilization system
The STERLINKĀ® FPS-15s Plus sterilization system can be utilized with the optional label-printer in order for the user to print the reports summarizing sterilization cycle information. This label- printer prints as sticker type the report for user convenience to manage the history of cycle information.
Figure 3.2 STERLINKĀ® FPS-15s Plus sterilizer
The printer is designed to be connected to the USB print connector on the rear side of the sterilizer. For the detailed information about the report, please refer to the Chapter 7 featuring “Reports and Dataā.
Ā
Figure 3.3 Label-printer for STERLINKĀ® FPS-15s Plus sterilization system
The STERLINKĀ® FPS-15s Plus system has three different modes (POUCH, POUCH Plus and CHAMBER mode) which are automatically initiated by using the barcoded printed on the sterilant cassettes of STERPACKĀ®, STERPACKĀ® Plus and STERLOADĀ®, respectively. The barcode contains information of the type and date of manufacture of the sterilant cassette.
Ā
Figure 3.4 Sterilant cassette of STERPACKĀ®
Figure 3.5 Sterilant cassette of STERPACKĀ® Plus
Figure 3.6 Sterilant cassette of STERLOADĀ®
Each cassette has two cells of sterilant which contain precisely measured amounts of hydrogen peroxide solution, and the two cells are used for repeating the same sterilization phases for one sterilization cycle. When the sterilization cycle is completed or stopped, the used cassettes should be handled with wearing protective gloves and have to be disposed according the right regulation. Please refer to the Chapter 5 featuring āOperationā to have more information on how to use the cassette.
CAUTION! CHECK EXPIRY DATE.
When you use the sterilant cassettes (STERPACKĀ®, STERPACKĀ® Plus, STERLOADĀ®), check the expiry date. If the date is expired, dispose and use new available sterilant cassettes.
CAUTION! HYDROGEN PEROXIDE MAY BE PRESENT.
Wear latex, PVC (vinyl), or nitrile gloves whenever handling a load after a cycle cancellation or error occurrence. Hydrogen peroxide liquid may be present on the load or in the chamber.
The STERLINKĀ® FPS-15s Plus sterilizer is designed for sterilization of both metal and nonmetal medical devices at low temperatures. The plasma sterilization process is a multiphase sterilization process that utilizes a combination of exposure to hydrogen peroxide vapor and plasma to complete the sterilization cycle.
The sterilizer can sterilize instruments which have diffusion-restricted spaces, such as the hinged portion of forceps and scissors. Medical devices with the following materials and dimensions can be processed in the STERLINKĀ® FPS-15s Plus sterilization cycles:
CAUTION! KNOW WHAT YOU CAN PROCESS.
Before processing items in the sterilizer, make sure you know how the STERLINKĀ® FPS-15s Plus sterilization process will affect the items. If you have questions, or if you are in doubt about the materials in your device, contact the medical device manufacturer or your local Plasmapp customer support representative for more information.
CAUTION! RISK OF WARRANTY VIOLATION.
Improper processing may limit liability for damage to processed instruments. The manufacturer can not warrant the damage of the instruments due to improper use.
The STERLINKĀ® FPS-15s Plus sterilizer is compatible for sterilizing the non-invasive and invasive medical devices, such as denture, endoscopes, ocular prosthesis, intraosseous transcutaneous amputation prosthesis, and surgical equipment.
The STERLINKĀ® FPS-15s Plus sterilization system is classified as Class IIb according to MDD 93/42/EEC and the system is intended to be used to disinfect medical devices including invasive devices.
There are a wide variety of materials and devices that can be sterilized in the STERLINKĀ® FPS- 15s Plus sterilizer. As more manufactures complete testing of their products with the sterilizer, the list of compatible items continues to expand. Information will be updated as new information becomes available. If the user has any doubt, please contact the medical device manufacturer.
CAUTION! RISK OF DAMAGE ON THE LOAD OR STERILIZER.
Do not attempt to sterilize items or materials that do not comply with the guidelines specified in this User manual. Consult the medical device manufacturer’s instructions or call your local Plasmapp customer support representative to determine whether an item can be sterilized by the STERLINKĀ® FPS-15s Plus sterilization system.
The following items should not be processed by the STERLINKĀ® FPS-15s Plus sterilization system.
All items must be cleaned, rinsed, and thoroughly dried before being placed in the STERLINKĀ® FPS-15s Plus sterilizer. Loads containing too much moisture may result an automatic cycle cancellation.
The cleaning and sterilization are two separated processes. As with all sterilization methods, proper cleaning of instruments and devices is a critical and necessary step prior to sterilization. All items must be cleaned, rinsed, and thoroughly dried before loading into the sterilizer.
Carefully inspect all instruments and devices for cleanliness and dryness and for flaws or damage prior to packaging. If visible soil or moisture is present, the item mush be re-cleaned and dried prior to sterilization. Devices and instruments with flaws or damages should be replaced or repaired before using.
The process of cleaning is necessary to remove organic and inorganic soil and debris from medical equipment. In this process, majority of micro-organisms are removed from the surface of the items. The process of sterilization inactivates all remaining spores and live micro-organisms.
Notes.
If you choose to package the instruments, proper preparation of trays, pouches, and instruments can minimize the possibility of the cycle cancellations and positive biological indicator (BI) results due to load-related problems. All instruments must be cleaned, rinsed, and thoroughly dried before loading into the sterilizer.
Only STERLINKĀ® instrument trays and accessories are recommended for use in the STERLINKĀ® FPS-15s Plus sterilizer. These instrument trays specially designed to allow diffusion of hydrogen peroxide. If you donāt use the vacuum-designed tray in Pouch mode, the sterilization cycle can be canceled due to the damage of pouch film.
Instrument trays should only be padded with polypropylene sterilization warp. Never use linen, cellulose, or any materials in the “Items not to be processed” section. The foam pads should not be used in instrument trays since they may absorb the hydrogen peroxide.
Packaging should be performed as follows.
The cassette should be precisely installed onto the loading block of the STERLINKĀ® FPS-15s Plus sterilizer. For the CHAMBER mode operation, the packaged devices are recommended to be loaded inside the chamber after loading the cassette (STERLOADĀ®) for your convenience.
WARNING! DO NOT USE IF PACKAGING IS DAMAGED.
Do not use if the package has been damaged or has not been properly sealed. If the sealing is not perfect, itās difficult to have confidence of asepsis, and the sterilization process can be cancelled.
CAUTION! INSERT CI (CHEMICAL INDICATOR).
Insert the CI in the packaging together with the product. After the sterilization cycle is completed, you can check if the product is working properly and the CI color has been changed properly.
CAUTION! BE CAREFUL, MAY BE CHAMBER HOT!
The temperature of the chamber may be hot. Wear protective gear and be careful when working inside the chamber and be careful of burns.
Each time you use the STERLINKĀ® FPS-15s Plus sterilizer, follow the instructions provided in the chapter 4 “Load preparation.” It is the operator’s responsibility to be familiar with the load preparation and safety information provided in this User manual.
Notes.
WARNING! HYDROGEN PEROXIDE IS CORROSIVE.
Concentrated hydrogen peroxide is corrosive to skin, eyes, nose, throat, lungs, and the gastrointestinal tract. Always were latex, PVC (vinyl), or nitrile gloves while removing items from the sterilizer following a cancelled cycle or error occurrence. Following a hydrogen peroxide may be present.
WARNING! HYDROGEN PEROXIDE DISPOSAL.
Hydrogen peroxide is designated as dangerous and hazardous medical wastes by American environment protection association and shall be disposed in accordance with the local regulation. (US waste disposal regulation: U.S. EPA 40 CFR 262)
CAUTION! USE ONLY CORD BY SUPPLIER.
If you use a power code/use cable code other than the one provided by our company, there is a risk of equipment malfunction or electric shock.
Figure 5.1 GUIs for the preheating and at ready stage
Number |
Name |
Description |
1 |
Preheating |
For components that require temperature control of chamber or vaporizer, to make the product ready the product will be preheat. |
2 |
Configuration |
The display can be moved into the sterilizerās configuration setup by touching this configuration icon. |
3 |
History |
The display can be turned into the sterilization management window by touching this history icon. |
4 |
ITS connection |
This section displays the present status of ITSTM connection. |
5 |
Time |
The current configurable time is displayed in Configuration menu. |
6 |
Sterilize |
The sterilizer starts the sterilization cycle by touching this icon. |
Confirming that sterilizing conditions were achieved during a sterilization cycle is one of important part of the sterilization process. Biological indicators are one way to ensure that your sterilizer is operating correctly.
Place a biological indicator in the STERPACKĀ®, STERPACKĀ® Plus or STERLINKĀ® chamber, respectively for the POUCH, POUCH Plus or CHAMBER mode. This biological testing is recommended to be performed at least once per day or specified by your facilityās policy.
While the sterilizer is warming up, you can use this time to prepare the load. Refer to the chapter detailing the load preparation information.
Mode |
Item description |
POUCH |
Total mass of the items should be less than 0.5 kg. |
POUCH Plus |
Total mass of the items should be less than 1.5 kg. |
CHAMBER |
Total mass of the items should be less than 5 kg. |
WARNING! POSSIBLE NON-STERILE DEVICE.
Improper sealing of the STERPACKĀ®, STERPACKĀ® Plus for the POUCH, POUCH Plus mode may result in either a non-sterile device or cycle cancellation. Seal tight the STERPACKĀ® by using a recommended sealing machine.
CAUTION! DO NOT REUSE.
The products (STERPACKĀ®, STERPACKĀ® Plus, STERLOADĀ®) are intended for single use only. Do not reuse, if you reuse the product an error will occur.
CAUTION! CHECK EXPIRY DATE.
When you use the sterilant cassettes (STERPACKĀ®, STERPACKĀ® Plus, STERLOADĀ®), check the expiry date. If the date is expired, dispose and use new available sterilant cassettes. The use of expired date cassette will occur an error.
CAUTION! HYDROGEN PEROXIDE MAY BE PRESENT.
Wear latex, PVC (vinyl), or nitrile gloves whenever handling a load after a cycle cancellation or error occurrence. Hydrogen peroxide liquid may be present on the load or in the chamber.
The STERLINKĀ® FPS-15s Plus sterilizer has three different modes which are operated by using the cassette of the STERPACKĀ®, STERPACKĀ® Plus and STERLOADĀ®. Place the cassette in the loading block as depicted in the following figure.
Figure 5.2 Loading cassettes of the STERPACKĀ® and STERLOADĀ®
WARNING! STERILIZATION SURFACES.
At the end of a cycle, the interior of the sterilizer may be hot. Do not touch the inside of the chamber or door with your bare or gloved hands. Allow the sterilizer to cool before touching interior surfaces.
WARNING! HAND CRUSH HAZARD.
The door of the sterilizer is designed to be manually opened and closed, and your hand can be injured by the door. Keep hands clear when opening or closing the door.
Figure 5.3 GUIs for the initializing and SRTM process
Number |
Name |
Description |
7 |
Barcode |
This section displays the barcode scanning result for the cassette loaded. |
8 |
Mode |
This represents the sterilization mode determined by the barcode. |
9 |
Door |
This section displays the door status. |
10 |
Back |
This icon is for cancelling the cycle. |
11 |
Mode |
This represents the mode of the sterilization cycle. |
12 |
Stop |
This icon is for stopping the cycle which is determined by the user. |
13 |
Progress |
This section displays the progress of the SRTM process. |
Notes.
WARNING! POSSIBLE NON-STERILE DEVICE.
Improper loading of the cassette may result in either a non-sterile device or cycle cancellation. The cassette should be precisely loaded on the cassette loading block of the sterilizer and properly locked.
CAUTION! HYDROGEN PEROXIDE MAY BE PRESENT.
Wear latex, PVC (vinyl), or nitrile gloves whenever handling a load after a cycle cancellation or error occurrence. Hydrogen peroxide liquid may be present on the load or in the chamber.
In the SRTM process, the drying, heating and measuring the residual water are included in the load condition.
Ā
Figure 5.4 GUIs for the drying and sterilization process
Number |
Name |
Description |
14 |
SRTM status |
The status image will be blinking during the drying process |
15 |
Sterilization status |
The status image will be blinking during the sterilization process. |
16 |
Sterilization time |
The remaining sterilization process time is displayed. |
When the sterilization process is successfully completed, the smart complete (SCTM) process is performed in order to ensure that there is no residual sterilant left on the sterilized instruments. After the relatively short SCTM process, the sterilization cycle is finished with summary of the cycle. Press the confirm switch to return to ready state.
Ā
Figure 5.5 GUIs for the SCTM process and completed summary stage
Number |
Name |
Description |
17 |
SCTM status |
The status image will be blinking during the SCTM process. |
18 |
Date |
This section displays the date of the sterilization cycle. |
19 |
Cycle time |
This section displays time for overall cycle time. |
20 |
Mode |
This section displays the mode of the finished sterilization cycle. |
21 |
Result |
This section displays the result of sterilization cycle. |
22 |
Confirm |
When the user clicks on āConfirmā button, the screen moves to ready state. |
23 |
|
When the user clicks on Print button, the label printer will print out the summary of the sterilization cycle information. |
There may be occasions when the user needs to cancel a cycle before it is completed. Touch the “STOP” button, and the screen displays a confirmation message. The user have to confirm the cycle cancellation to stop the cancellation process.
Figure 5.6 GUIs for one of the sterilization process and user confirm
Number |
Name |
Description |
24 |
STOP |
This icon is for cancelling the cycle. |
25 |
Confirm |
This icon is for confirming the cancellation. |
26 |
Cancel |
This icon is for withdrawing the cancellation. |
When the cycle cancellation is initiated, it cannot be stopped by the user. Since the sterilization cycle is not properly performed.
Figure 5.7 GUIs for one of the sterilization process and user confirm
Number |
Name |
Description |
27 |
Caution for door handling |
It highlights that door should not be handled by the user during the stopping process. |
28 |
Caution for sterility |
The status image will be blinking during the sterilization process. |
29 |
User confirm |
When the user confirm is selected, the screen moves to ready state. |
Even the stopping process includes purification process, sterilant can be left on the loads. Wear protective gloves when handling the load and used cassettes. As depicted in the final GUI, the sterility assurance level may not be obtained, and it requires to restart a new sterilization cycle with rewrapping using new packaging material.
WARNING! POSSIBLE NON-STERILE DEVICE.
Cycle cancellation may result in a non-sterile device, and it requires to restart a new sterilization cycle with rewrapping using new packaging material.
CAUTION! HYDROGEN PEROXIDE MAY BE PRESENT.
Wear latex, PVC (vinyl), or nitrile gloves whenever handling a load after a cycle cancellation or error occurrence. Hydrogen peroxide liquid may be present on the load or in the chamber.
When you confirm the completed cycle, the sterilized load can be processed by inspecting the chemical indicators and by processing the biological indicator.
After ensuring that the chemical indicators exhibit the correct color change, and the cycle printout shows that all parameters were met, the sterilized load is ready for immediate use, following your facility’s policy. If the chemical indicators do not exhibit the correct color change, investigate the cause and repackage and reprocess the load.
Remove the biological indicator from the load and process it according to its Instruction for use. Refer to the biological indicator flow chart on the following pages.
The STERLINKĀ® FPS-15s Plus sterilizer utilizes the embedded software for automated implementation of the STERLINKĀ® sterilization process. This chapter contains how to control the configuration of STERLINKĀ® FPS-15s Plus low temperature plasma sterilizer.
Users with supervisor-level access authorities (see below) are permitted to perform a set of restricted sterilizer functions. These functions are not used in daily sterilizer operation and some of them are designed to control access, manage system records, and perform advanced diagnostic functions.
The STERLINKĀ® FPS-15s Plus sterilizer can be configured to require that the users enter a valid password in order to control the system configuration. There are three levels of access available. Each is associated with a different subset of permitted operations.
Operator-level access is designed to permit a user to perform tasks associated with the daily operation of the sterilizer. These authorities allow a user to:
Supervisor-level access includes all of the authorities of Operator-level access and additionally provides the ability to:
Service-level access is only for use by the Plasmapp Customer Service Representatives.
The Additional utilities menu in the “Configuration” is available to users with Supervisor or Service-level access authorities. The Additional utilities menu allows supervisors to configure the time setting, sterilizer system setting, and diagnostic test.
Figure 6.1 GUISs for configuration and system setting
Number |
Name |
Description |
1 |
Number key |
The number keys are provided for entering password and system setting. |
2 |
Del key |
The key is for deleting the number entered. |
3 |
Password display |
This section displays the password entered. The default setting for the password is ā1111ā. |
4 |
OK key |
The key is for confirming the password. |
5 |
Back |
This icon is for going back to the user screen for ready. |
6 |
Display selection |
The display time for the screen saver can be selected by touching the circle icon. |
7 |
Plus key |
The sound volume can be increased by touching this plus key. |
8 |
Minus key |
The sound volume can be decreased by touching this plus key. |
9 |
Sound bar |
The sound bar displays the established volume. |
10 |
Door open |
When the door of the sterilizer can not be opened, this function can open the door urgently. |
11 |
Pump Heating |
When the ambient temperature is low or the product is not used for long time, this function can start the preheating of vacuum pump. |
The cycle report is automatically created and displayed by the STERLINKĀ® FPS-15s Plus sterilizer when the sterilization cycle is completed. The displayed report summarizes the cycle information of the cycle date, time, process mode and the result of the sterilization cycle.
Figure 7.1 GUIs of cycle summary when the cycle is passed and failed
Number |
Name |
Description |
1 |
Date |
This section displays the date of the sterilization cycle. |
2 |
Cycle time |
This section displays time for overall cycle time. |
3 |
Mode |
This section displays the mode of the finished sterilization cycle. |
4 |
Result |
This section displays the result of sterilization cycle. |
5 |
User confirm |
When the user confirm is selected, the screen moves to ready state. |
6 |
|
When the print is selected, the label printer will print out the summary of the sterilization cycle information. |
7 |
Caution |
This section describes caution information when the sterilization fails. |
The STERLINKĀ® FPS-15s Plus sterilizer can create, store, display, and print the cycle data. When connected to internet, the sterilizer can upload the cycle history files to the ITSTM server. Cycle history data contains very detailed sterilization cycle information of each SRTM, sterilization and SCTM process. The data includes identifying information about the sterilizer, time, date, cycle duration information, process data from the sensors of the sterilizer. Information is extracted from the cycle history data to produce the printed report.
The history data is stored in the memory of the STERLINKĀ® FPS-15s Plus sterilizer. The memory holds data form the last 50 cycles. After 50 cycles are completed, the oldest cycle history record is overwritten with new data from the 51st cycle. If the sterilizer is configured with internet connection to ITSTM server, the cycle history data can be periodically uploaded to the server.
The STERLINKĀ® FPS-15s Plus sterilizer is the highest quality sterilizer that performs reliable sterilization cycles. As the sterilizer may be deteriorated by continuous usages, the sterilizer also needs proper maintenance to guarantee user safety and reliable sterilization cycle. This chapter describes what kind of works and parts are required for the maintenance of the STERLINKĀ® FPS-15s Plus sterilization system.
The following maintenance procedures are performed by the user, when needed:
Notes.
The sterilizer exterior can be cleaned with a soft cloth and a mild, nonabrasive detergent solution if necessary. When cleaning the sterilizer exterior, follow the guidelines:
The sterilizer interior chamber can be cleaned with a soft cloth or damp soft cloth with no running water. When cleaning the sterilizer interior chamber, follow the guidelines.
Notes.
WARNING! STERILIZATION SURFACES.
At the end of a cycle, the interior of the sterilizer may be hot. Do not touch the inside of the chamber or door with your bare or gloved hands. Allow the sterilizer to cool before touching interior surfaces.
WARNING! HAND CRUSH HAZARD.
The door of the sterilizer is designed to be manually opened and closed, and your hand can be injured by the door. Keep hands clear.
CAUTION! POSSIBLE DAMAGE ON THE STERILIZER.
Do not use the steel brush (wire brush), steel foam (steel wool), compound and detergent containing chloride compound. They may damage the sterilizer or its electrodes. Please remove all detergent, fabric or thread left in the chamber after cleaning.
CAUTION! HYDROGEN PEROXIDE MAY BE PRESENT.
Wear latex, PVC (vinyl), or nitrile gloves whenever handling a load after a cycle cancellation or error occurrence. Hydrogen peroxide liquid may be present on the load or in the chamber.
When the label-printer roll is empty, the roll is required to be replaced manually as following.
The usage level of each registered sterilizer will be indicated in the user registered ITSTM system. When the usage level suggests for sterilizer maintenance, please contact your local Plasmapp customer support representative.
Hydrogen peroxide (Chemical Formula: H2O2) in the cassettes of STERPACKĀ®, STERPACKĀ® Plus and STERLOADĀ® is designated as dangerous and hazardous waste by American Environment Protection Association and shall be disposed in accordance with the local regulation. (US waste disposal regulation: U.S. EPA 40 CFR 262.). The cassettes are NOT medical devices and should be purchased separately from STERLINKĀ®.
CAUTION! HYDROGEN PEROXIDE MAY BE PRESENT.
If a cycle cancels and the items in the load appear wet, hydrogen peroxide may be present. Wear latex, PVC (vinyl), or nitrile gloves while removing the items from the chamber and wiping off the items with a damp cloth.
When the STERLINKĀ® FPS-15s Plus sterilizer system is reinstalled from initial place to the another, the system shall be moved by the authorized technicians. If there is no continuous sterilization cycle, it is required to turn off the power switch of the sterilizer and pull out the power cord from the power outlet with following storage condition.
Name |
Value |
Humidity |
30-85% |
Atmosphere pressure |
70ā106 kPa |
Temperature |
10-40ā |
When the system is reactivated after long stop, the user shall contact the manufacturer of the sterilization system and the authorized person of the manufacturer to take a proper instruction. Moreover, the equipment shall not be reinstalled where the power cord is difficult to handle.
In the event that disposal of the system is necessary, the system may be return to the manufacturer, recycled with a local recycler, or disposed of in a local landfill. Disposal of infectious waste and electronic circuit boards are regulated by the U.S. Environment Protection Agency and most international environmental agencies. Please contact Plasmapp or your local Plasmapp customer support representative for additional information.
Most sterilizer operating problems are accompanied by a system message. These messages are useful in determining the source of the problem. In many cases you can take remedial actions to correct the source of the problem and thereby return the sterilizer to normal operation. In other cases, the problem is caused by a component failure that requires adjustment or repair by the manufacturer or the local Plasmapp customer support representative. If you are unable to identify the cause and solve the problem, please contact Plasmapp or your local Plasmapp customer support representative.
The STERLINKĀ® FPS-15s Plus sterilizer system can perform the fully automated sterilization cycle. The system can display self-status with LED light of green, blue, and red at the following status.
LED Color |
System status |
Green |
Ready for the sterilization (Blinking during preheating process) |
Blue |
Sterilization cycle is completed. (Blinking during sterilization cycle) |
Red |
Blinking when the error occurs. |
Ā
Figure 8.1 Sterilizer status with different LED colors
The STERLINKĀ® FPS-15s Plus sterilization system will be automatically updated by the Plasmapp when the user confirms this update. If the system finds a new software version at the ITSTM server, the following alarm will be popped up when the system is restarted.
When the user confirms this software update, it will take several minutes for completing the update and the system will be rebooted when completed. The update may be failed by the unstable internet connection and can be postponed depending on the user.
Figure 8.2 GUIs for software update confirm and updating
Number |
Name |
Description |
1 |
Confirm |
This icon is for confirming the software update. |
2 |
Cancel |
This icon is for postponing the software update. |
CAUTION! POSSIBLE DAMAGE ON THE STERILIZER.
The power-off during the software update may damage the sterilizer system. If it happens, contact the local Plasmapp customer service representative.
The STERLINKĀ® FPS-15s Plus sterilization system is designed to provide alarm messages with the intuitive figures representing the predictable source for the user errors. When the user confirms, the error should be checked and understood by the user. If the problems persist, please contact Plasmapp or local Plasmapp customer service representative.
Figure 9.3 GUIs for user errors
Number |
Name |
Description |
3 |
Confirm |
The user should confirm the error when the source of the problem is checked and understood. |
4 |
DOOR NOT CLOSED |
Probable cause: The door is not closed. Suggestion: Check door closing and try again. |
5 |
INCOMPLETE SEALING |
Probable cause: The STERPACKĀ® and STERPACKĀ® Plus sealing is not properly performed. Suggestion: Re-seal tightly and try again. |
6 |
DESCRIPTION |
Describes the causes and solutions of the problems. |
āIncomplete sealingā error may occur when the pouch is damaged by sharp medical device in POUCH mode. It is recommended to use the exclusive tray.
The STERLINKĀ® FPS-15s Plus sterilization system is designed to initiate automatically the sterilization cycle according to the barcode information provided by the sterilant cassettes. The predictable error source is presented with the intuitive figures, and the user should identify the source and confirm. If the problems persist, contact local Plasmapp customer service representative.
Figure 8.4 GUIs for the errors related with the sterilant cassettes
Number |
Name |
Description |
7 |
Confirm |
The user should confirm the reason of the error and press Confirm button. |
8 |
USED CASSETTE |
Probable cause: The used cassette is tried to be reused. Suggestion: Try again with a new cassette. |
9 |
EXPIRED CASSETTE |
Probable cause: The expired cassette is tried to be used. Suggestion: Try again with a new cassette or check time setting. |
10 |
INVALID CASSETTE |
Probable cause: The barcode of the cassette is invalid. Suggestion: Try again with a new cassette. |
11 |
BARCODE NOT DETECTED |
Probable cause: The cassette is not detected. Suggestion: Clean the barcode window or try again. |
Many system errors are incorporated with the problems with the loads, but the STERLINKĀ® FPS- 15s Plus sterilization system also can have a problem resulting from a component failure. If the problems persist, contact Plasmapp or local Plasmapp customer service representative.
Figure 8.6 GUIs for the system errors
Number |
Name |
Description |
12 |
Confirm |
The user can confirm this system error after contacting customer service representative. |
13 |
SYSTEM ERROR |
Probable cause: A component failure results in preheating error. Suggestion: Contact the customer service or restart the system. |
14 |
SYSTEM STABILIZING |
Probable cause: A component failure results in completing the cycle. Suggestion: Wait until recovering system and try again. |
Note.
If the power of sterilization system is abnormally shut off during the sterilization process, the following screen will appear. To ensure user safety, the purification process will be active it can take from a few minutes to tens of minutes, after the status will be ready. Even the purification is well done, you can find the residual sterilant.
Ā
WARNING! POSSIBLE NON-STERILE DEVICE.
Any error may result in a non-sterile medical device, and it requires to restart a new sterilization cycle with rewrapping using new packaging material.
CAUTION! HYDROGEN PEROXIDE MAY BE PRESENT.
Any error may result in failure of removing hydrogen peroxide. Wear latex, PVC (vinyl), or nitrile gloves when handling the loads and cassette.
Youbong Lim, CEO of Plasmapp. Co,. Ltd.
Name |
Description / Specifications |
Figure |
STERPACKĀ® |
Impermeable pouch containing sterilant for POUCH mode
|
|
STERPACKĀ® Plus |
Impermeable pouch containing sterilant for POUCH Plus mode
|
|
STERLOADĀ® |
Cassette containing sterilant for CHAMBER mode
|
Name |
Description / Specifications |
Figure |
TyvekĀ® pouch (W100) |
Device sterile packaging pouch for CHAMBER mode
|
|
TyvekĀ® pouch (W200) |
Device sterile packaging pouch for CHAMBER mode
|
|
TyvekĀ® pouch (W300) |
Device sterile packaging pouch for CHAMBER mode
|
Name |
Description / Specifications |
Figure |
Chamber Tray |
Chamber Inner Tray – Size: 250 mmĆ 350 mmĆ 105 mm
|
|
STERPACKĀ® Tray |
Special vacuum tray for STERPACKĀ®
|
|
STERPACKĀ® Plus Tray |
Special vacuum tray for STERPACKĀ® Plus – Size: 160 mmĆ 260 mmĆ 50 mm
|
Name |
Description / Specifications |
Figure |
Special Cart |
Cart with locking wheel – Size: 483 mm Ć 660 mm Ć 603 mm
|
|
Label-Printer |
External thermal printer – Size: 120 mm Ć 102 mm Ć 146 mm
|
|
Label Sticker Roll |
Label sticker roll for label-printer
|
|
Chemical indicator tape |
Chemical indicator for sterilization cycle monitor
|
|
Chemical indicator strip |
Chemical indicator for sterilization cycle monitor
|
1. Product name: Low temperature plasma sterilizer
2. Model: STERLINKĀ® FPS-15s Plus
3. Manufacturer
Company |
Plasmapp Co., Ltd. |
Address |
83, Jukdong-ro, Yuseong-gu, Daejeon, 34127, Republic of Korea |
Tel |
+82-42-716-2115 |
Fax |
+82-42-716-2116 |
Website |
4. Manufacturing business license number: 5307 (MDITAC, Republic of Korea)
5. Medical device manufacturing permit number: 17-4579 (MDITAC, Republic of Korea)
6. Serial number and manufacturing date
7. European certification body
Company |
MTIC InterCert S.r.l |
Address |
Via G. Leopardi, 14, 20123 Milano (MI), Italy |
Tel |
+39 02 97071800 |
Fax |
+39 02 9308176 |
Website |
Description |
Unit |
|||
Dimensions |
433 (W) Ć 614 (D) Ć 437 (H) |
mm |
||
Effective chamber volume |
14 |
liter |
||
Cycle time |
POUCH mode |
SRTM / SCTM Process |
3 |
min |
Sterilization Process |
4 |
|||
Overall Cycle |
7 |
|||
POUCH Plus mode |
SRTM / SCTM Process |
6 |
||
Sterilization Process |
8 |
|||
Overall Cycle |
14 |
|||
CHAMBER mode |
SRTM / SCTM Process |
21 |
||
Sterilization Process |
15 |
|||
Overall Cycle |
36 |
|||
Sterilization |
Sterilant: Hydrogen peroxide (concentration: 58%) Injection / penetration, diffusion and purification by plasma |
|||
Sterilizing pressure |
Final vacuum pressure |
< 3.0 |
torr |
|
Vacuum leakage |
< 0.1 |
torr/sec |
||
Pressure range |
0.0 ā 760 |
torr |
||
Cycle temperature |
< 56 |
oC |
||
Display |
7” TFT LCD touch screen |
|||
Power input |
100-120 / 220-240 VAC, 50/60 Hz |
|||
Max. power consumption |
1.0 |
kVA |
||
Electrical shock class |
Class 1 (Protection standard and class for electrical shock) |
|||
Life cycle |
15 years |
User manual for the STERLINKĀ® FPS-15s Plus sterilization system
Manufacturer: Plasmapp Co., Ltd.
83, Jukdong-ro, Youseong-gu, Daejeon, 34127
Republic of Korea Website: http://www.plasmapp.co.kr
TEL: +82-42-716-2115
FAX: +82-42-716-2116
Authorized US representative: Vetovation Inc.
Raleigh, NC
Website: http://www.vetovation.com
TEL: 919-247-0328
If you need to print this PDF or save for later
click below to download your copy.
[button size=”medium” style=”secondary” text=”Download PDF” link=”https://vetovationnew.instawp.xyz/wp-content/uploads/2019/11/What-Can-I-Sterilize-in-STERLINK-003-Copy.pdf” target=”none”]
*Any devices processed in the STERLINKĀ® System must be within the cleared claims of the sterilizer
If you have questions about whether a particular device can be sterilized in the STERLINK Ā® System, please call the device manufacturer
ā +82-42-716-2115
*List of materials does not apply to trays and containers or other packaging materials. Please refer to the STERLINKĀ® User Manual for information on appropriate packaging materials for use in the STERLINKĀ® System. *DelrinĀ® and TeflonĀ® are registered trademarks of E. I. DuPont de Nemours and Company. ULTEMĀ® is a registered trademark of the GE Company. KRATONā¢ is a trademark of KRATON Polymers U.S. L.L.C.
If no/don’t know:Ā Please call the medical device manufacturer for information on how to properly sterilize this device.
If yes: Continue to Step 2.
If no/don’t know:Ā Proceed sterilization. Pouch Mode – Fits in Pouch. Chamber Mode – Fits in Chamber.
If yes: Continue to Step 3.
If no/don’t know: Please call the medical device manufacturer for information on how to properly sterilize this device.
If yes: Continue to Step 4.
*Test standard of sterilization performance using biological indicator (BI)
*If the lumens do not conform to these dimensions, please call the medical device manufacturer for information on how to properly sterilize these devices. Lumens not conforming to these dimensions should not be processed in the STERLINKĀ® System.
If yes: Proceed sterilization. Pouch Mode – Fits in Pouch. Chamber Mode – Fits in Chamber.
If you need to print this PDF or save for later
click below to download your copy.
[button size=”medium” style=”secondary” text=”Download PDF” link=”https://vetovationnew.instawp.xyz/wp-content/uploads/2019/12/PlasmappSterlink-EN-14-page-brochure.pdf” target=”none”]
A low-temperature gas plasma sterilizerĀ to sterilize a wide range of medical devices
The STERLINKĀ®FPS–1Ss Plus gas sterilization veterinary system is a low temperature plasma sterilizer to inactivate microorganisms for a broad range of metal and nonmetal medical devices and surgical instruments at low temperature. This product is reliable and provides a variety of methods of sterilization.
STERLINKĀ®can sterilize medical devices by diffusing hydrogen peroxide vapor into the chamber or pouch. It rapidly sterilizes medical instruments and materials without leaving toxic residues. All stages of the plasma sterilization cycle does not damage compatible instruments which are sensitive to heat and moisture.
This sterilizer can be used for metal and non-metal medical devices and can sterilize instruments with high lumen characteristics and micro sized equipments.
It consistently provides the Sterility Assurance Level (SAL) of 10-6, as defined by U.S. Food and Drug Administration (FDA) and international standards, only when used within the materials and geometric requirements given.
The devices have been pre-validated to the SAL of 10Ā·5 based upon high resistance conditions, including lumens within the claim lengths and mated surfaces.
Fast Sterilization
Convenient POWER SAVING
Eco-Friendly
Perfect DISINFECTION
STERPACKĀ® (Pouch Mode)
World first pouch-type sterilization during 4 minutes is possible with the patented direct sterilant injection technology from Plasmapp.
POUCH MODE
STERPACKĀ® Plus (Pouch Plus Mode)
Large capacity pouch reflecting market needs.
Ā POUCH Plus MODE
STERLOADĀ® (Chamber Mode)
It is sterilized immediately in 15 minutes using a large chamber of 14 liters to increase user efficiency.
CHAMBER MODE
Flexible Sterilization modes depend on the capacity
The STERLINKĀ®FPS-15s Plus sterilizer provides a smart sterilization process that combines Smart Ready (SRā¢) and sterilization process and Smart Complete (SCā¢) to ensure sterilization efficiency, reliability and user safety. The gas plasma sterilizer system is designed to operate only with the sterilant cassettes of STERPACKĀ®, STERPACKĀ® Plus and STERLOADĀ®. Each cassette has individual barcode which is scanned by the sterilizer to start the sterilization cycle automatically according to the barcode identifying the type of the cassettes.
The SRā¢ process is provided to measure residual moisture left on the medical devices and to perform optimized heating and drying process according to the analysis.
The sterilization process consists of the two consecutive and equal phases, and the critical process parameters in each phase are identical. The validation of the sterilization process is performed by using the half-cycle overkill method to demonstrate the 10-6 SAL. The following table provides a brief description for each cycle.
[table id=14 /]
The lumen test is mandatory for invasive sterilization. The lumen structure consists of long tube connected with BI container. It is more difficult to be sterilized against the lumen with longer length and smaller diameter. The STERLINKĀ®FPS-15s Plus has been tested with more challenging lumen structure.
We guarantee the best sterilization standard in reference to SAL of 106. After the test with BI inside the lumen, you can check whether the sterilization is reliable by cultivating the BI in the incubator. All the sterilization test report are certified by Korean MFDS and CE/MOD.
Hydrogen Peroxide Gas Sterilization Requires 4 Key Elements
These 4 key elements are the core basis for achieving optimal Hydrogen Peroxide Gas Sterilization
Each Barcode on STERPACKĀ®, STERPACKĀ®Plus and STERLOADĀ®allows for sterilization record tracking for individual patients. Barcode for STERPACKĀ®& STERPACKĀ®Plus & STERLOADĀ®Tracking Production Information included to assure STERPACKĀ®& STERPACKĀ®Plus & STERLOADĀ®validity. It helps prevent the use of expired cassettes. Also, barcode on cassettes find sterilization mode by itself.
Instrument Tracking System is a real-time sterilization monitoring system. Available as an analysis of actual usage data of STERPACKĀ®, STERPACKĀ®Plus and STERLOADĀ® as a remote device diagnostic tool. Provide advanced services that deliver accurate data analysis and immediate delivery to end users.
Starting sterilization cycle
Cycle in progress and completed
The drying process and sterilization process will be initiated after measuring the load condition at the SRā¢ process.
When the gas sterilization veterinary process is successfully completed, the smart complete (SCā¢) process is performed in order to ensure that there is no residual sterilant left on the sterilized instruments. After the relatively short SCā¢ process, the sterilization cycle is finished with summary of the cycle. Press the confirm switch to return to ready state.
[table id=15 /]
STERPACKĀ®
Impermeable pouch containing sterilant for POUCH mode
STERPACKĀ®Plus
Impermeable pouch containing sterilant for POUCH Plus mode
STERLOADĀ®
Cassette containing sterilant for CHAMBER mode
Special Cart
Cart with locking wheel
Label-Printer
External thermal printer
STERSEALĀ®
Rotary sealer by HAWO
Label Sticker Roll
Label sticker roll for label-printer
Chemical Indicator Tape
Chemical indicator for sterilization cycle monitor
Chemical Indicator Strip
Chemical indicator for sterilization cycle monitor:
TyvekĀ® pouch (W 100)
Device sterile packaging pouch for CHAMBER mode
TyvekĀ® pouch (W 200)
Device sterile packaging pouch for CHAMBER mode
TyvekĀ® pouch (W 300)
Device sterile packaging pouch for CHAMBER mode
Plasmapp is an innovative manufacturing company specializing in plasma technology. Based on the core technology of KAIST plasma physics laboratory, we are creating a market with differentiated products in the medical and industrial plasma device industries. Developed for medical markets, the world’s first direct injection technology is certified and commercialized.
In the industrial plasma device market, we have developed and commercialized a plasma source (LJPSĀ®) capable of stable surface treatment at atmospheric pressure, thus improving the productivity of the secondary battery manufacturing process.
Think Plasma, Think Plasmapp!
Plasmapp Co.,Ltd. Values innovation, diligence, creativeness and technical know-how to create smart plasma applications to satisfy every needs of plasma-tech industry. It is our mission to provide high quality and cutting-edge plasma solutions.
Best regards,
CEO of Plasmapp
Youbong Lim
If you need to print this PDF or save for later
click below to download your copy.
[button size=”medium” style=”secondary” text=”Download PDF” link=”https://vetovationnew.instawp.xyz/wp-content/uploads/2021/01/Plasma-quick-start-guide.pdf” target=”none”]
[arve url=”https://vimeo.com/703308964″ mode=”normal” play_icon_style=”vimeo” maxwidth=”800″ /]
This video will describe the information needed prior to delivery and installation of the Sterlink Hydrogen Peroxide Gas Plasma Sterilization System.
[arve url=”https://vimeo.com/703320599″ /]
This video will describe the installation process for the Sterlink Hydrogen Peroxide Gas Plasma Sterilization System and provide information that will need to be completed prior to using the product.
The VetOvation Endoscopy system enables flexible and regid scopes for many applications in veterinary medicine. The system is affordable and easy to use. Please contact VetOvation at 919-247-0328 for additonal information.